Sunday, October 23, 2011

Damned Electronics!

A Sample of what I have to make a presentation on in electronics on tuesday.... Damnit its hard material!

 

 

The Diac

This is a bi-directional trigger diode used mainly in firing Triacs and Thyristors in AC control circuits. Its circuit symbol (shown in figure 3a) is similar to that of a Triac, but without the gate terminal, in fact it is a simpler device and consists of a PNP structure (like a transistor without a base) and acts basically as two diodes connected cathode to cathode as shown in figure 3b.

Figure 3. The Diac Circuit symbol and an equivalent diagram using diodes.

Figure 3a, Diac Circuit SymbolFigure 3b, Equivalent circuit using diodes
The DIAC is designed to have a particular break over voltage, typically about 30 volts, and when a voltage less than this is applied in either polarity, the device remains in a high resistance state with only a small leakage current flowing.
Once the break over voltage is reached however, in either polarity, the device exhibits a negative resistance as can be seen from the characteristic curve in Figure 4.

Figure 4. Typical Diac Characteristics.

Figure 4, Typical Diac Characteristics
When the voltage across the diac exceeds about 30 volts (a typical break-over voltage) current flows and an increase in current is accompanied by a drop in the voltage across the Diac. Normally, Ohm's law states that an increase in current through a component causes an increase in voltage across that component; however the opposite effect is happening here, therefore the Diac exhibits negative resistance at break-over.
In the simple power control circuit in Figure 2 the Diac is used to trigger a Triac by the "Phase Control" method. The AC mains waveform is phase shifted by the RC circuit so that a reduced amplitude, phase delayed version of the mains waveform appears across C. As this wave reaches the break over voltage of the Diac, it conducts and discharges C into the gate of the Triac, so triggering the Triac into conduction. The Triac then conducts for the remainder of the mains half cycle, and when the mains voltage passes through zero it turns off. Some time into the next (negative) half cycle, the voltage on C reaches break over voltage in the other polarity and the Diac again conducts, providing an appropriate trigger pulse to turn on the Triac.
By making R a variable value, the amount of phase delay of the waveform across C can be varied, allowing the time during each half cycle at which the Triac fires to be controlled. In this way, the amount of power delivered to the load can be varied.
Note that in practical control circuits using Thyristors, Triacs and Diacs, large voltages are switched very rapidly. This can give rise to serious RF interference, and steps must be taken in circuit design to minimise this. Also as Mains is present in the circuit there must be some form of safe isolation between the low voltage control components (e.g. the Diac and phase shift circuits) and the mains "live" components, e.g. the Triac and load. This can easily be achieved by "Opto-coupling" the low voltage control circuit to the high voltage power control (Triac or SCR) part of the circuit.

Friday, October 14, 2011

Crazy Bastard!


If only my back muscles could look like Sharma's..... HAha. What a frigin guy!


Tuesday, October 11, 2011

A couple "Off The Grid" Videos

Off the Grid is a small mini series made by my Hero Les Stroud!

Good little series. Though definately not perfect. I still enjoyed the general struggle and project.

These are the first two parts of it. You can find the rest via YouTube.com


Hope you enjoy!

Tuesday, October 4, 2011

Great Day!!!! ................

So, I wake up more exausted than a 110 year old man, which makes perfect sense cause I only got 9.5 hours of sleep!!!!!!!!!!!! ????????


Get to school, 5 minutes late. GREAT!


Barely make it through till lunch, and I decide to head over to speak to my co-worker face-to-face and see if I can convince him to take my shift on Sunday, So I can have a fantastic little rock climbing trip down to the states.


Get in my truck.... and ........ Nothing. Not even a click. Its fucked.


No big deal. Just means Ill have to call Co-Worker. I call and he tells me straight up, its not going to happen. Great!!! I cant do anything all long-weekend cause of one damn shift.!


My classroom Buddy came and jumped the truck for me after classes...


Then it died a block down the street. (After I told him not to worry about me)


After a good walk home, Jumped on my motorcycle to get around, and it starts raining hard. Plus I have no head light on the damn bike and it starts getting really dark, faster than I thought.


. And.... Im just generally grouchy.... LoL

(Oh ya, and the guys I had to bail on for the climbing trip, I also had plans to hit the climbing gym tonight, but forget that shit!)


I hope that was a satisfactory RANT, to make all other RANTS pale in comparison.

Been A GREAT! Day!

Enjoy the rest of yours!!!

Saturday, October 1, 2011

A cute little Game of Thrones video I found!

Game of Thrones RPG (Uncut) 

Very funny video!! But you have to have watched the season 1 of Game of Thrones to enjoy...
Enjoy!